HOME    CONTROLLER AND LOAD CELL    LOAD CELL    RH-HC
RH-HC

RH-HC

The elastic structure of the sensor is special, with good bending and torsion resistance, thereby improving the natural frequency and anti overturning, anti deviation, anti-interference and other characteristics of the sensor. The installation and connection of the sensor can use specialized connecting components, which is convenient and reliable for installation.

Product Details

• Rated load:1000 / 1500kg

• Sensitivity:2.0±0.02%mV/V

• Total error:±0.5% F.S

• Creep error:±0.02% F.S

• TC SPAN:±0.02% F.S / 10℃

• Working temperature:-20~+60℃

• Input impedance:760±10Ω

• Output impedance:700±2Ω

• Safe overload:150% F.S

• Ultimate overload:200% F.S

• Excitation:5~12VDC

• Max.excitation:15VDC

• Insulation impedance:≥5000MΩ

• Protection class:IP67 / IP68

• Construction:Alloy Steel

• Cable length:1.8m

• Size(mm):110×30×65mm